• Encapsulated Motors Temperature Conditions

    Conditions Temp. of the Water
    Without Motor Operation
    Max. Trip Temp. / Resistance Setting
    (for standard lead length)
    Motor operating at nameplate output
    with 0.16 m/sec flow past the motor
    10 °C 40 °C / 115.5 Ω
    15 °C 44 °C / 117.0 Ω
    20 °C 48 °C / 118.6 Ω
    25 °C 51 °C / 119.7 Ω
    30 °C 55 °C / 121.3 Ω
    Motor that has been derated
    with 1 m/sec flow past the motor
    35 °C 59 °C / 122.8 Ω
    40 °C 63 °C / 124.3 Ω
    45 °C 66 °C / 125.5 Ω
    50 °C 70 °C / 127.0 Ω
    55 °C 74 °C / 128.6 Ω
    60 °C 78 °C / 130.1 Ω

    6″ PT100 Standard Encapsulated Motors Model Numbers

    Kit Number Motor Type Wire Insul. Max. Medium Temp. Lead [mm²] Lead Length [m]
    305 327 903 6″ all ratings ½ – 13 UNC
    Europe motors starting 07. 2002
    US Motors starting 11.2001 on
    Rubber 60 °C 3X0.5 10

    8″ PT100 Standard Encapsulated Motors Model Numbers

    Kit Number Motor Type Wire Insul. Max. Medium Temp. Lead [mm²] Lead Length [m]
    305 326 902 30 – 45 kW (type 2.1) Rubber 60 °C 3X0.5 10
    305 326 901 55 – 150 kW (type 1) Rubber 60 °C 3X0.5 10

    Encapsulated Motors HiTemp Temperature Conditions

    Conditions Temp. of the Water
    Without Motor Operation
    Max. Trip Temp. / Resistance Setting
    Motor operating at nameplate output
    with 0.16 m/sec flow past the motor
    50 °C 60 °C
    60 °C 70 °C
    70 °C 80 °C
    75 °C 85 °C
    80 °C 90 °C
    90 °C 100 °C

    6″ Encapsulated Motors HiTemp Model Numbers

    Kit Number Motor Type Wire Insul. Max. Medium
    Temp.
    Lead
    [mm²]
    Lead Length
    [m]
    156 098 111K 4 – 30 kW Silicone 90 °C 4X0.35 10
    156 098 112K Silicone 90 °C 4X0.35 130

    8″ Encapsulated Motors HiTemp Model Numbers

    Kit Number Motor Type Wire Insul. Max. Medium
    Temp.
    Lead
    [mm²]
    Lead Length
    [m]
    156 098 116K 30 – 110 kW (type 1) Silicone 90 °C 4X0,35 10
    156 098 117K Silicone 90 °C 4X0,35 130